Plastic Factory 9.5mm -31mm Adjustable Ball Valve Lockout for Double Roll Valves
Part No. : ABVL03
Adjustable Ball Valve Lockout
The product description
The commonly used valve locks are ball valve locks, butterfly valve locks, gate valve locks, rotary valve locks and multi-purpose valve locks.
Ball valve lock is mainly used to lock ball valve, to protect the safety of ball valve.
Part No. | Description |
ABVL03 | Suitable for pipe diameter from 9.5mm(1/2”) to 31mm (2 3/4”) |
General rules for energy isolation
1 applicable conditions for energy isolation
When entering, transforming or maintaining a certain equipment, facility or device, external energy should be cut off to avoid accidental release of energy. Such as power sources, fluid and pressure sources, mechanical drives and control systems.
2. Provisions for electrical isolation
Device source power off and locked; Such as power distribution sources for equipment, facilities and installation systems;
The signal isolation is a special form of electrical isolation, which is completed in the form of isolation and bypass.
Mechanical isolation regulations
Process isolation method
Single valve isolation
Double valve isolation and discharge method
Single valve isolation plus blind plate
Isolation of confined space entry
Pipeline disassembly isolation method
Double partition and insert blind board method
General requirements for isolation operations
To control by issuing quarantine certificates;
The isolator and the isolator shall not be the same person;
Process isolation selection diagram should be used as the basis for determining mechanical isolation method or type;
If there is any change, the feasibility of risk assessment to identify the risk and isolation;
Qualification of isolator;
On-site verification prior to quarantine;
Each isolation point should have a separate label and padlock.
Particular requirements for isolation of oil and gas pipelines
Single valve isolation and oil and gas pipeline isolation;
If the valve can not be locked in the closed position, set a person to continue to monitor;
The operation under single-valve isolation should be short term, if too long, should consider changing the operation method;
Do not heat work in a single - valve isolated area.
The basic elements of an isolation certificate
Equipment and purpose of isolation
Segregation applicant
Approval of the quarantine application
Information for all isolation points
Isolation method
Isolation type
Line instrument diagram (P&ID)
Time of isolation
Isolator's signature
Effect of isolation
Release time