Lockey 1/2" to 2 3/4" Adjustable Ball Valve Lockout with Front Back Foot Board
Part No. : ABVL04F
Adjustable Ball Valve Lockout
Part No. | Description |
ABVL03 | Suitable for pipe diameter from 9.5mm(1/2”) to 31mm (2 3/4”) |
ABVL03F | Suitable for pipe diameter from 9.5mm(1/2”) to 31mm (2 3/4”), with front and back foot board |
ABVL04 | Suitable for pipe diameter from 13mm(1/2”) to70mm (2 3/4”) |
ABVL04F | Suitable for pipe diameter from 13mm(1/2”) to 70mm (2 3/4”) , with front and back foot board |
ABVL05 | Suitable for pipe diameter from 73mm(2 4/5”) to 215mm (8 1/2”) |
Safety valve series - safety flange ball valve lock product features:
1. Easy to use and easy to install.
2. Use advanced polypropylene material, complete insulation and strong and durable.
3. Good resistance to high temperature, corrosion and solubility, and can be used in various harsh environments.
4. Excellent fracture resistance and wear resistance, which can extend the service time of ball valve.
5. Designed in accordance with the requirements of American OSHA standards and internationally accepted
6. Multiple colors are selected to facilitate the division of labor management.
Responsibility - isolate the witness
Check isolation process
Verify that all steps are performed
Assist isolation personnel or isolation team leader
Isolation procedure
For complex isolation, isolation procedures are necessary
Complex isolation
Greater than or equal to 2 isolation points or greater than or equal to 2 energy sources
Isolation procedure - preparation
It must be prepared by a certified isolation planner
Under certain conditions can be written by the isolation personnel
Identify the items of equipment to be isolated
Check the workplace
Determine the isolation limit
Identify hazards and control measures
Use the energy source checklist to ensure that all energy sources are identified
Isolation program - content
Program name isolation point location isolation point type isolation point identification label
Action - need to place isolation point to safe (isolated) location
Validation step
Isolation device requirements - isolation lock
Use only company-supplied locks
Do not change the lock's appearance or paint
Never attempt to bypass or operate an isolation point with a lock
If lock or key is lost, report to supervisor immediately
Only used to lock isolation points to unisolated locations
Never rely on someone else's lock - never lock your own lock to another lock ring
Only for isolation purposes
Isolation device requirements - identification label
Personal locks - personal information
Equipment lock - unit - unit isolation board identification number
Device lock - isolation - isolator personal information
To the lock ring of the lock
Not for other purposes
Note: can also be used for group locking