Lockey 60Amp Nylon PA Miniature Circuit Breaker Lockout Mcb Locks TBLO Tie Bar Lockout
Part No.: TBLO
Miniature Circuit Breaker Lockout
Part No. | Description |
POS | POS (Pin Out Standard), 2 holes required, fit up to 60Amp |
PIS | PIS (Pin In Standard), 2 holes required, fit up to 60Amp |
POW | POW (Pin Out Wide), 2 holes required, fit up to 60Amp |
TBLO | TBLO (Tie Bar Lockout), no hole in breakers required |
Introduction to circuit breaker lockout:
small circuit breaker locks: small circuit breaker locks is made from high strength resin, the unique design of the shark teeth fixed screws, stainless steel material is qualitative with provide stronger circuit breaker handle occlusion, with adjustable damper, and the locks on both sides of the scale, for a variety of circuit breaker handle the length of the switch trip submitted by effective control handle is loose, make it more secure.
Test the delivery winch
1. Maintenance of a single hoist, the hoist is overhauled stop, the CAM controller switch to the "0" position, and the CAM controller is hung on the "maintenance is prohibited closing" maintenance plate.
2. Remove the steel wire rope and trolley of the single hoist being inspected;
3. Check and repair 2 hoisting machines. When the hoisting machine under repair stops, cut off the power in the power box of the hoisting machine.
Maintenance and repair vehicle
1. In addition to the failure of the big car to operate, the driving stops at the position of the maintenance platform.
2. Drive up and down after the vehicle stops.
3. Cut off the power supply of the vehicle, and set "no maintenance during operation" on the power box.
4. Maintenance by two or more persons shall not be carried out by one person.
5. No live operation is allowed. Check the electricity before operation, and check the maintenance after confirming no electricity.
6. All electrical tools must have reliable insulation before use.
7. Electricians must take good insulation measures before operation, and keep good lighting on the work site.
8. It is forbidden for maintenance workers to touch the strike wire with their hands and feet in electric welding operations.
9. Install leakage protector on mobile appliances and lamps, and the lighting power supply voltage shall not exceed 36V.
10. The primary and secondary insulation of the welding machine is intact, and the power cord and welding gun are not exposed or damaged.
11. Oxygen and acetylene cylinders must be kept at a safe distance of more than 5 meters, and oxygen and acetylene cylinders should be kept away from the ignition point.
12. Welding machine welding wire, electrical equipment wire source and oxygen, acetylene hose is not wound together.
13. Tools shall be placed in the designated place during maintenance. Tools shall not be thrown during transmission. Tools shall be counted after work.